ADDRESSABLE TYPE FIRE ALARM SYSTEM

Addressable Fire Alarm Systems differ from conventional systems in a number of ways and certainly add more flexibility, intelligence, speed of identification and scope of control. For this reason Addressable Fire Alarm Systems are the natural choice for larger premises and more complex system requirements. In an  addressable system detectors are wired in a loop around the building with each detector having its own unique 'address'. The system may contain one or more loops depending upon the size of the system and design requirements. The Fire Control Panel 'communicates' with each detector individually and receives a status report, i.e. 'Healthy', 'In Alarm' or 'In Fault', etc. As each detector has an individual 'address' the fire alarm control panel is able to display/indicate the precise location of the device in question, which obviously helps speed the location of an incident and for this reason 'zoning' of the system is not necessary, although it may be done for convenience.

Addressable fire alarm systems offer benefits in speed of detection, identification of the location of a fire and easier maintenance. Addressable fire alarm systems also offer tolerance to faults in the system wiring, which allows a single pair of wires to be used to connect up to 200 devices to the system, allowing cost savings in the wiring of large systems. In larger installations, the benefits of improved maintenance and reduced cabling cost are overwhelming. The price difference between Addressable systems and conventional systems has narrowed to such an extent that even for small installations, the use of an Addressable fire alarm system should be considered.

 

Top

FIRE PANEL   Features :  

Addressable_Fire_Panel


Modular configuration allowing for easy extension
Easy adaptation to country-specific regulations and conditions
Complete set-up with up to 46 modules per control panel
Interconnection of up to 32 Panel Controllers and Remote Keypads (by August 2009)
Loop or bus connection with redundancy
Connection to BIS Building Integration System via OPC server
Control of up to 4096 addresses (stand-alone panel),
or of up to 32512 addresses of a network with 2032 addresses per control panel (by August 2009)
Installation and auto-detection of functional modules by simply inserting them into the Panel Rail
Large LCD display with touch screen


Top

DETECTOR   Features :  


detector



Combination of optical, thermal and chemical sensors with intelligent evaluation electronics.
Earliest detection of lightest smoke (TF1) with the double-optical smoke detectors with Dual-Ray technology
Detector properties adapted to cater for room usage
Drift compensation in optical and gas measurement section
Maintains LSN loop functions in the event of wire interruption or short-circuit thanks to two integrated isolators
Extended system parameters of improved LSN technology

Top

INVISIBLE DETECTOR   Features :   


invisible_detector



Modern, ultra-flat design
Smooth, easily-cleaned detector surface
Innovative fastening mechanism
High reliability
Maintains LSN loop functions in the event of wire interruption or short-circuit thanks to two integrated isolators
Extended system parameters of improved LSN Technology

Top

BEAM DETECTOR   Features :  


beam_detector



Operates over distances between 30 ft (9 m) and 350 ft (107 m)
Six levels of switch-selectable sensitivity
Built-in alignment sights and tamper protection
Automatic range adjustment, signal synchronization, and contamination adjustment
Remote indicator plate annunciates voltage, trouble, and alarm conditions
Switch-selectable alarm signal delay
Auxiliary Form C alarm relay

Top

SOUNDER   Features :  


sounder


Volume up to 101.3 dB(A)
Maximum current consumption less than 3,9 mA
Up to 100 sounders per loop
Constant sound pressure level between 22 V and 33 V operating voltage
Synchronization without delay
Easy to install
Long lifetime and modern design
32 different tone variants can be selected (incl. DIN Tone)
Maintains LSN loop functions in the event of wire interruption or short-circuit thanks to two integrated isolators


Top

STROBE   Features :  


strobe


Quick installation
No additional cabling or power supply
Low consumption thanks to LED-technology
Synchronized flash rate of 1 Hz


Top

MCP   Features :  


MCP


Adjustment of the Manual Call Point after alarm triggering
Automatic or manual detector addressing via rotary switch possible
Indicator LED for alarm or for inspection evaluation
Call point query routines with evaluation and multiple transmission
Individual call point identification
Maintains LSN loop functions in the event of wire interruption or short-circuit thanks to two integrated isolators