CONVENTIONAL TYPE FIRE ALARM SYSTEM

Conventional panels have been around ever since electronics became small enough to make them viable. They are no longer used frequently in large buildings, but are still used on smaller sites such as small schools, stores, restaurants, and apartments. A conventional system employs one or more initiating circuits, connected to sensors (initiating devices) wired in parallel. These sensors are devised to decrease the circuits resistance when the environmental influence on any sensor exceeds a predetermined threshold. In a conventional system the information density is limited to the number of such circuits used. A small map of the building is often placed near the main entrance with the defined zones drawn up, and LEDs indicating whether a particular circuit/zone has been activated. Another common method is to have the different zones listed in a column, with an LED to the left of each zone name, or to use an LCD interface to display information.

 

FIRE PANEL   Features :   Technical Specification :


Fire_Panel


  • Fully complies with UL-864 9th Edition and NFPA-72.
  • 4/8 Class B conventional initiating device circuit (IDC).
  • All zones accept smoke detectors and any normally open contact device.
  • Any Zone can be configured as Alarm or supervisory Zone.
  • 2 Class B Notification Appliance Circuits (NAC).
  • Operates on 220v 50Hz, AC Mains power supply.
  • Standby (battery) backup 24v DC power supply with built in charger.
  • Rugged CRCA sheet with powder coated finish.
  • All field wiring circuits are supervised.


Primary Power 

220VAC ± 10%, 50Hz, 2.5Amps.
Standby Power 
 24v D.C (2 Nos of 1 2v, 12Ah Sealed Lead acid battery).
Operating Condition 
Operating Temperature 15- 350 C/60-95° F.
Relative Humidity 93±2% RH (non-condensing) at 32 ±2° C/90 ±30 F.
Charging Circuit 
Charging Voltage 28.4V, ±0.2V
Charging Current 750mA (Max.).

Top

MCP   Features :   Technical Specification :


MCP

 


  • Three types of Manual Call Points (Metal, Alluminium, Plastic).
  • Alarm status is indicated By Red colour LED.
  • Operates on 24 VDC.
  • Red, Green, Yellow colour . Plastic.


Operating Voltage

24 VDC
Operating Current
30mA
Colour
Red, Yellow, Green (Alluminium & Metal - Red)
Material
Metal, Plastic & Aluminium.
Size
Round Type(Aluminium)
Outer dia (cover) 100mm
Inner Dia (shell) 80mm
Depth with out cover 50mm (with cover 70mm)

Top

SOUNDER   Features :   Technical Specification :


sounder

 


  • Operates on 24 VDC.
  • 90 db @ 1 Mtr.
  • Low Current Device.


Operating Voltage

24 VDC
Operating Current
150 to 200 mA
Power
5 Watts
Sound Level
90 db at 1 Mtr
Colour
Red
Material
C.R.C.A. Sheet
Size
140 * 120 * 65mm (Height * Width * Depth)
Weight
1 Kg(App)

Top

RESPONSE INDICATOR   Features :   Technical Specification :


response_indicator

 


  • Alarm status is indicated By Red colour LED.
  • Operates on 12 VDC.


Operating Voltage

12 VDC
Operating Current
10 mA
Alarm Indication
RED LED
Colour
Ivory
Material
Metal
Size
63 x 63 mm

Top

REPEATER PANEL   Features :   Technical Specification :


repeater_panel

 


  • CRCA sheet with powder coated finish.
  • Operates on 24 VDC.
  • Fire / Fault status in unambiguous coloured LED indication.
  • System on indications.
  • Silence facility.
  • Lamp test facility.
  • RS485 for Repeater Communication (Use shielded or twisted wire (CAT5E or CAT6)).


Operating Voltage

24 VDC
Operating Conditions
-10 to 45° C, 95% RH Max
Operating Current
20 - 35 mA
Quiescent Current
50mA Plus 0.125mA per Zone
Colour of the Panel
Broken White (Red, Red Texure - Optional)
Alarm Output
Standard Common Output
0.2Amps

Top

 